Reminder for the First Semester of Academic Year 2026: Proper Collection and Segregation of Laboratory Waste Liquids with Emphasis on Chemical Compatibility – Please Refer to the Laboratory Management Regulations
1. Laboratory waste liquids and chemicals must be properly segregated according to their chemical compatibility. Waste liquids that are incompatible with each other (refer to the Safety Data Sheets (SDS)) must be collected and stored separately in different waste containers. Each container must be labeled with the appropriate hazard pictograms and its main chemical constituents.
2. Records must be maintained for all waste liquids added to the waste containers, including the names of the main chemicals, quantities discarded, concentrations, and other relevant information.
3. Acidic waste liquids are classified into organic acids, inorganic acids, and oxidizing acids. Each type must be collected and stored separately in different waste containers.
4. Before collecting acidic waste liquids, 10–20% water may be added to the waste container to dilute the concentration of subsequently collected waste liquids.
5. When the amount of waste liquid reaches approximately 16 liters (80% of the container's capacity), please prepare a replacement container and follow the established procedures to apply for transfer to the temporary waste storage facility managed by the Office of Environmental and Occupational Safety and Health.
6. When the amount of waste liquid reaches approximately 10 liters (50% of the container's capacity) and has been stored for more than one year (one academic year), please follow the established procedures to apply for transfer to the temporary waste storage facility managed by the Office of Environmental and Occupational Safety and Health.
7. The Laboratory Waste Compatibility Chart must be posted in a clearly visible location in the laboratory, and all laboratory personnel must be informed of its contents.
8. Waste liquid containers must be placed inside secondary containment trays with a capacity of at least 1.1 times the container's volume to prevent leakage and spills.
9. The Office of Environmental and Occupational Safety and Health website also provides a laboratory incident reporting procedure and a flowchart for determining waste liquid classifications. For further details, please refer to the Laboratory Management Regulations.